ProSYS Version 8.xx - Supplementary Instructions 5
d. Press to confirm.
e. Repeat the above steps for other BUS detectors.
2. Assign the iWISE BUS detectors to a Zone:
a. From the main Engineer menu select [2] Zones > [1] One by One.
b. Select the zone number that you want to assign the BUS detector.
Note:
If you defined a virtual BUS Zone Expander, select a zone number from the virtual zones (defined
by the BUS Zone expander).
c. Define Partitions, Groups, Zone Type and Zone Sound.
d. In the Termination category, select [5] BUS Zone followed by
.
e. Select the BUS zone number to assign to the programmed zone. The type field
will be updated automatically when selecting the zone.
f. Press
. The loop response category is not applicable to a BUS zone.
g. Press
, assign a label and press .
3. If you want to use the extra wired zone input on the iWISE BUS detector:
a. Repeat steps a. – c. in step 2 above.
b. In the Termination category, select the relevant BUS Zone input termination:
[07] BUS Zone Input N/C
[08] BUS Zone Input EOL
[09] BUS Zone Input DEOL
[10] BUS Zone Input N/O
[11] BUS Zone Input TEOL
c. Press
. Select the BUS zone that the input zone belongs to. The Type field
will be updated automatically when selecting the zone.
d. Press
. Define the loop response time.
e. Press
, assign a label and press .
4. Configure the iWISE BUS detector parameters:
a. From the main Engineer menu select [2] Zones > [0] Miscellaneous > [3] BUS
Zone Parameters.
b. Select the zone that the BUS Zone was assigned to and press
.
c. Use the following tables to configure the parameters for the relevant iWISE BUS
detector.